Technical data of the MT-HV

Supply voltage

12 to 32 V DC

Power input

10 to 40 W

Current draw

max. 1 A

Battery type

RRC2040

Ambient temperature

Recommended: 10 to 35 °C

Working range: 0 to 45 °C

Storage temperature: -10 to 60 °C

Suitable for humid environment?

no

Altitude

max. 2000 m above NHN (normal height null)

Relative air humidity

approx. 10 to 90 % (not condensating)

Continuous operation

Yes

Weight

approx. 1.7 kg

Dimensions

300 x 360 x 80 mm (L x W x H)

IP degree of protection

IP20

Overload protection

max. 1 kV

Measuring channels

1 (galvanically isolated)

Measured variables of the HV modules

  • High-voltage measurement up to 1 kV
  • Potential equalization measurement
  • Insulation resistance measurement
  • Resistance measurement (service disconnect plug)

Interfaces

  • USB-C
  • Bluetooth®
  • RJ45

Ranges

Voltage

  • Measuring range: ± 1000 V DC
  • Resolution: 0.1 V
  • Precision: ± (1 % of reading + 2 digits)

Insulation resistance measurement

  • Measuring range: 10k...10 GΩ
  • Test voltage: variably adjustable to 1000 V DC in steps of 10 V
  • Resolution: 0.1
  • Precision: ± (3 % of reading + 3 digits)

Resistance (service disconnect plug)

  • Measuring range: 0...10 Ω
  • Resolution: 0,01 Ω
  • Measuring current: 200 mA
  • Precision: ± (2.5 % of reading + 4 digits)

Potential equalization measurement

  • Measuring range: 0...10 Ω
  • Resolution: 0,01 Ω
  • Measuring current: 200 mA
  • Precision: ± (2.5 % of reading + 4 digits)

High-voltage test lead

red

  • Length: 1500 mm
  • Handpiece with function button
  • With 4 mm test connection for manufacturer-specific test adapters
  • incl. plug-on measuring probe

black

  • Length: 1500 mm
  • Handpiece
  • With 4 mm test connection for manufacturer-specific test adapters
  • incl. plug-on measuring probe