Performing a System Test

The following tests are performed consecutively by the BPC-Tool during the system test:

NOTICE

notice

A blue amp clamp (CP 700) is required for the complete system test. Without an amp clamp, the current intensity is not measured during the starter and alternator tests. The resistor test is not applicable at all.

Proceed as follows to perform the system test:

  1. Connect the BPC-Tool to the battery (see operating instructions for the BPC-Tool).
  2. Insert the electrical plug connection of the clamp meter into the ST3 connector of the BPC-Tool with the arrow pointing up.
  3. Select >Optional HGS Tools< in the main menu.
  4. Select Battery diagnostics with .
  5. Select >System test<.
  6. Open the list under Temperature measurement with .
  7. Select the required type of temperature measurement.
  8. Repeat steps 6 to 7 for another selection.
  9. Open the virtual keypad under Cold cranking amps [A] with where necessary.
  10. Enter a value.
  11. Confirm your entry with .
  12. Start the function System test under Diagnostic type with .
  13. The connection to the BPC-Tool is established.
  1. The system test is started.

From here, the system test is controlled using the keys on the BPC-Tool (see operating instructions of the BPC-Tool).

A summary of the system test is displayed on the BPC-Tool and is automatically imported into the device.